[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
high B-factors for some ncs copies
*** For details on how to be removed from this list visit the ***
*** CCP4 home page http://www.dl.ac.uk/CCP/CCP4/main.html ***
Hi all,
I am refining a structure with six molecules in the asymmetric unit.
The data set is only to 2.8 A resolution. I thought I was done with it,
having R-free at about 23% and R-work at about 18%. But when I checked
average B-factors, here is what I saw:
Chain name Atoms Bave Bsdv Bmin Bmax
M1A 2894 33.57 18.77 2.00 100.00
M1B 2894 42.50 19.15 2.00 100.00
M2A 2894 ** 58.96 ** 24.67 4.87 100.00
M2B 2894 ** 56.48 ** 25.61 2.00 100.00
M3A 2894 34.52 21.01 2.00 100.00
M3B 2894 40.98 21.16 2.00 100.00
WAT 80 31.76 12.33 5.44 69.18
Two copies of my molecule have alarmingly high average B-factors.
Refinement has been done primarily in X-plor, with one round of
refinement in CNS. Strong ncs restraints have been used throughout.
How should I check whether these high B-factors indicate a problem with
chains m2a and m2b, or whether they simply have high B-factors? Would
rigid-body refinement be appropriate? Or annealed omit maps? Or should
I remove the ncs restraints on those two copies? I'd really like to
finish soon, and don't want to waste too much time...
Thanks in advance,
Susan
--
--------------------------------------------------------------------
Susan Heffron
Dept. of Physiology and Biophysics
University of California, Irvine
Irvine, CA 92697
U.S.A.
phone: (949) 824-4625
FAX: (949) 824-8540
e-mail: sheffron@uci.edu
--------------------------------------------------------------------