[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[ccp4bb]: Riding Hydrogens
*** For details on how to be removed from this list visit the ***
*** CCP4 home page http://www.ccp4.ac.uk ***
Hi All,
Another subject for debate. I am in the process of refining a 2.1 angstrom
structure using the latest version of Refmac. The default for restrained
refinement seems to be to generate all hydrogens. This doesn't seem very
resonable at 2 angstrom resolution. I usually change the default to not
include the hydrogens, but I was a bit sleepy one afternoon and forgot to
change the default. Upon noticing that I had set it wrong, I decided to
re-run refinement again. Surprisingly, I found that adding the hydrogens
in lowered both R and R free by about 1%. Still skeptical, I tried a 2.3
angstrom data set, in and early stage of model building, here are the
results:
without hydrogens:
REMARK 3 FIT TO DATA USED IN REFINEMENT.
REMARK 3 CROSS-VALIDATION METHOD : THROUGHOUT
REMARK 3 FREE R VALUE TEST SET SELECTION : RANDOM
REMARK 3 R VALUE (WORKING + TEST SET) : 0.23753
REMARK 3 R VALUE (WORKING SET) : 0.23305
REMARK 3 FREE R VALUE : 0.32008
REMARK 3 FREE R VALUE TEST SET SIZE (%) : 5.2
REMARK 3 FREE R VALUE TEST SET COUNT : 1196
with hydrogens:
REMARK 3 FIT TO DATA USED IN REFINEMENT.
REMARK 3 CROSS-VALIDATION METHOD : THROUGHOUT
REMARK 3 FREE R VALUE TEST SET SELECTION : RANDOM
REMARK 3 R VALUE (WORKING + TEST SET) : 0.23091
REMARK 3 R VALUE (WORKING SET) : 0.22655
REMARK 3 FREE R VALUE : 0.31141
REMARK 3 FREE R VALUE TEST SET SIZE (%) : 5.2
REMARK 3 FREE R VALUE TEST SET COUNT : 1196
So I am unclear on on the requirements for adding the hydrogens on in
refinement. At what resolutions do they become justified? Why are they
lowering my R and R-free?
Thanks,
Jason