                50% twinning diagnostics

Are anomalous correlations between twinned reflections any different
between, say, 50% twinned P3 and true P3112? Generally - not very much.
Ideally (no errors) corr=1 for both. Except for a subgroup of
reflections! If twinning operator accidently relates I+ and a copy of I-
then corr=1 for a twin and corr=-1 for a true spacegroup. I found it
rather useful.

Dmitriy Alexeev, Edinburgh.